7 diagnostics, Diagnostics – JLG G12-55A AccuPlace Service Manual User Manual
Page 167

9.49
G10-55A & G12-55A AccuPlace
Electrical System
9.15.7
Diagnostics
The table below lists Diagnostic Help Messages that the
Control System shall communicate to the Analyzer. The
goal is to help locate the source of any problem which
occurs on the vehicle.
Note: All items are available in Access Level 3, unless
designated with a superscript of the lowest access level
in which the items can be displayed (i.e., "PUMP
MANFLD CMD2" denotes that this parameter is available
in Access Levels 1, and 2).
#
Indicates that parameter should be displayed only if the
machine is configured to utilize the component.
Diagnostics
Submenu
(Displayed on
Analyzer 1
st
Line)
Parameter
(Displayed on
Analyzer 1
st
Line)
Parameter Value
(Displayed on
Analyzer 2
nd
Line)
Description
GROUND:
AP FLT RST SW:
CLOSED/OPEN
Displays status of AccuPlace Fault Reset switch.
CONT AUX HYD SW: CLOSED/OPEN
Displays status of Continuous Auxiliary
Hydraulics switch.
BOOM RIDE SW:
#
CLOSED/OPEN
Displays status of Boom Ride Mode Enable
switch.
AP MODE LAMP:
ON/OFF
Displays status of AccuPlace Mode Lamp.
AP FLT RST LAMP:
ON/OFF
Displays status of User Fault Lamp.
BOOM RIDE LAMP:
#
ON/OFF
Displays status of Boom Ride Mode Lamp.
LIFT CMD:
UP/DOWN XXX.X% Displays reprocessed joystick lift direction &
demand.
TELE CMD:
IN/OUT XXX.X%
Displays reprocessed joystick telescope switch
direction & demand.
FORK CMD:
UP/DOWN XXX.X% Displays reprocessed joystick fork lift direction &
demand.
AUX CMD:
AUX 1/AUX 2
XXX.X%
Displays reprocessed joystick Auxiliary
Hydraulics direction & demand.
SWAY OUTPUT
LEFT/RIGHT
XXX.X%
Displays UGM sway output command direction &
demand.
SWAY CMD:
LEFT/RIGHT
XXXXmA
Displays UGM sway output current command
direction & demand.
SWAY FDBK:
XXXXmA
Current feedback measured on Sway Valve
Return.
LT STAB OUTPUT:
UP/DOWN XXX.X% Displays UGM Left Stabilizer output command
direction & demand.
LT STAB CMD:
UP/DOWN XXXXmA Displays UGM Left Stabilizer output current
command direction & demand.
LT STAB FDBK:
XXXXmA
Current feedback measured on Left Stabilizer
Valve Return.
RT STAB OUTPUT:
UP/DOWN XXX.X% Displays UGM Right Stabilizer output command
direction & demand.
RT STAB CMD:
UP/DOWN XXXXmA Displays UGM Right Stabilizer output command
direction & demand.