JLG G12-55A AccuPlace Service Manual User Manual
Page 207

9.89
G10-55A & G12-55A AccuPlace
Electrical System
ISP – PRESSURE
SENSOR
VOLTAGE OUT
OF RANGE
4581
ISP controller detects too
low or high voltage from
Pressure Sensor 1 or 2.
N
Cycle power to clear DTC; if DTC still
present, replace controller (Refer to
Section 8.8.11, “Valve Controllers.”).
CAUTION: HIGH OIL PRESSURE
WITHIN VALVE AND CONTROLLER.
LIFT VALVE –
PRESSURE TOO
HIGH
4582
Lift valve controller detects
too high pressure from
Pressure Sensor 1 or 2.
N
Cycle power to clear DTC; if DTC still
present, remove controller and clean
around pressure transducers. Ensure
transducer gaskets are in place and
reinstall/torque in sequence (Refer to
Section 8.8.11, “Valve Controllers.”). If
fault is still present, controller replacement
is required.
CAUTION: HIGH OIL PRESSURE
WITHIN VALVE AND CONTROLLER.
Removing controller may cause cylinder
leakage. Brace/block boom before
removing controller.
TELESCOPE
VALVE –
PRESSURE TOO
HIGH
4583
Tele valve controller detects
too high pressure from
Pressure Sensor 1 or 2.
N
Cycle power to clear DTC; if DTC still
present, remove controller and clean
around pressure transducers. Ensure
transducer gaskets are in place and
reinstall/torque in sequence (Refer to
Section 8.8.11, “Valve Controllers.”). If
fault is still present, controller replacement
is required.
CAUTION: HIGH OIL PRESSURE
WITHIN VALVE AND CONTROLLER.
Removing controller may cause cylinder
leakage. Brace/block boom before
removing controller.
FORK VALVE –
PRESSURE TOO
HIGH
4584
Fork valve controller detects
too high pressure from
Pressure Sensor 1 or 2.
N
Cycle power to clear DTC; if DTC still
present, remove controller and clean
around pressure transducers. Ensure
transducer gaskets are in place and
reinstall/torque in sequence (Refer to
Section 8.8.11, “Valve Controllers.”). If
fault is still present, controller replacement
is required.
CAUTION: HIGH OIL PRESSURE
WITHIN VALVE AND CONTROLLER.
Help Message
1
DTC
Fault Condition
(for configurable items,
fault applies only if
configured)
Fault
Requires
AccuPlace
Reset?
Action(s)