JLG G12-55A AccuPlace Service Manual User Manual
Page 195

9.77
G10-55A & G12-55A AccuPlace
Electrical System
TELESCOPE 
VALVE COIL 2 –
SHORT TO 
GROUND OR 
OPEN CIRCUIT
4556
Tele valve controller detects 
too large of an error between 
coil drive current and 
feedback. Detection shall 
occur during Startup and 
Tele Retract.
Y
Inspect wiring for physical damage.
Check for continuity through this circuit.
On the 12-pin valve controller connector, 
verify that the TELE V2 wire in pin 3 and 
TELE V2 RTN in pin 8 are properly seated, 
as well as the connections on the V2 coil.
Current Command and Feedback values 
may be monitored via the Analyzer under 
Diagnostics/Tele Valve to help with the 
assessment.
FORK VALVE 
COIL 2 – SHORT 
TO GROUND OR 
OPEN CIRCUIT
4564
Fork valve controller detects 
too large of an error between 
coil drive current and 
feedback. Detection shall 
occur during Startup and 
Fork Tilt Down.
Y
Inspect wiring for physical damage.
Check for continuity through this circuit.
On the 12-pin valve controller connector, 
verify that the FORK V2 wire in pin 4 and 
FORK V2 RTN in pin 10 are properly 
seated, as well as the connections on the 
FORK V2 coil.
Current Command and Feedback values 
may be monitored via the Analyzer under 
Diagnostics/Fork Valve to help with the 
assessment.
AUX VALVE COIL 
2 – SHORT TO 
GROUND OR 
OPEN CIRCUIT
4568
Fork valve controller detects 
too large of an error between 
coil drive current and 
feedback. Detection shall 
occur during Startup and 
Aux 2.
Y
Inspect wiring for physical damage.
Check for continuity through this circuit.
On the 12-pin valve controller connector, 
verify that the AUX V2 wire in pin 6 and 
AUX V2 RTN in pin 8 are properly seated, 
as well as the connections on the AUX V2 
coil.
Current Command and Feedback values 
may be monitored via the Analyzer under 
Diagnostics/Fork Valve to help with the 
assessment.
LIFT VALVE COIL 
3 – SHORT TO 
GROUND OR 
OPEN CIRCUIT
4550
Lift valve controller detects 
too large of an error between 
coil drive current and 
feedback. Detection shall 
occur during Startup and Lift 
Up.
Y
Inspect wiring for physical damage.
Check for continuity through this circuit.
On the 12-pin valve controller connector, 
verify that the LIFT V3 wire in pin 5 and 
LIFT V3 RTN in pin 9 are properly seated, 
as well as the connections on the V3 coil.
Current Command and Feedback values 
may be monitored via the Analyzer under 
Diagnostics/Lift Valve to help with the 
assessment.
Help Message
1
DTC
Fault Condition
(for configurable items,
fault applies only if
configured)
Fault
Requires
AccuPlace
Reset?
Action(s)