9.51
G10-55A & G12-55A AccuPlace
Electrical System
RT STAB JOY CMD:
±XXX%
Displays position in percentage for this axis;
positive is lower voltages and negative is higher
voltages.
RT STAB SIGNAL:
X.XV
Provides voltage signal output for joystick.
RT STAB NEUT SW:
NEUTRAL/OUT OF
NEUTRAL
Indicates whether joystick switches designate out-
of-neutral position.
BOOM
COMPONENTS:
BOOM ANGLE LEFT: ±XX.X DEG
Displays boom angle of left-mounted CAN sensor
with negative degrees below horizontal; 90°
means invalid reading.
BOOM ANGLE LEFT: XXXXX COUNTS
Displays raw counts of left-mounted CAN sensor.
BOOM ANGLE RT:
±XX.X DEG
Displays boom angle of right-mounted analog
sensor with negative degrees below horizontal;
90× means invalid reading.
BOOM ANGLE RT:
XXXXX COUNTS
Displays raw counts of right-mounted analog
sensor.
TELE LENGTH:
XXX.X INCHES
Displays total boom length reading; 900” means
invalid reading.
TELE LENGTH:
XXXXX COUNTS
Displays raw counts of boom length sensor.
FORK ANGLE:
±XXX.X DEG
Displays fork angle with negative angles below
horizontal. This calculation uses Attachment F to
relate Fork Angle to Cylinder Length (displayed
only if MTS configured).
FORK LENGTH:
XXXXX.X INCHES
Displays calibrated length in inches of Fork
Length sensor.
FORK LENGTH:
XXXXX COUNTS
Displays raw counts of Fork Length sensor.
ISP BOOM ANGLE:
2
±XXX.X DEG
Displays Boom Angle computed by ISP.
ISP BOOM LENGTH:
2
XXX.X INCHES
Displays Boom Length computed by ISP.
ISP FORK ANGLE:
2
±XXX.X DEG
Displays Boom Angle computed by ISP.
Diagnostics
Submenu
(Displayed on
Analyzer 1
st
Line)
Parameter
(Displayed on
Analyzer 1
st
Line)
Parameter Value
(Displayed on
Analyzer 2
nd
Line)
Description