9.93
G10-55A & G12-55A AccuPlace
Electrical System
LIFT VALVE –
WIRING NOT
MAPPED
PROPERLY
45103 The order of the Lift Valve
current feedback wiring in
the 12-pin connector does
not match what the controller
expects.
Y
Verify that the proper signal wires are
connected in terminations 3-6 and the
proper current feedback wires are
connected in terminations 7-10 of the 12-
pin connector. Check the integrity of the
controller pins and the harness
terminations by removing each socket,
inspecting, and reinserting.
Verify that the proper controller is
installed. Disconnect the ISP, Tele Valve,
and Fork Valve controllers and cycle
power. Under Diagnostics/Versions, verify
that only the UGM, Joystick and Lift Valve
are reporting a software version (??? for
the other controllers).
TELESCOPE
VALVE – WIRING
NOT MAPPED
PROPERLY
45104 The order of the Tele Valve
current feedback wiring in
the 12-pin connector does
not match what the controller
expects.
Y
Verify that the proper signal wires are
connected in terminations 3-6 and the
proper current feedback wires are
connected in terminations 7-10 of the 12-
pin connector. Check the integrity of the
controller pins and the harness
terminations by removing each socket,
inspecting, and reinserting.
Verify that the proper controller is
installed. Disconnect the ISP, Lift Valve,
and Fork Valve controllers and cycle
power. Under Diagnostics/Versions, verify
that only the UGM, Joystick and Tele
Valve is reporting a software version (???
for the other controllers).
FORK VALVE –
WIRING NOT
MAPPED
PROPERLY
45105 The order of the Fork Valve
current feedback wiring in
the 12-pin connector does
not match what the controller
expects.
Y
Verify that the proper signal wires are
connected in terminations 3-6 and the
proper current feedback wires are
connected in terminations 7-10 of the 12-
pin connector. Check the integrity of the
controller pins and the harness
terminations by removing each socket,
inspecting, and reinserting.
Verify that the proper controller is
installed. Disconnect the ISP, Lift Valve,
and Tele Valve controllers and cycle
power. Under Diagnostics/Versions, verify
that only the UGM, Joystick and Fork
Valve is reporting a software version (???
for the other controllers).
Help Message
1
DTC
Fault Condition
(for configurable items,
fault applies only if
configured)
Fault
Requires
AccuPlace
Reset?
Action(s)