beautypg.com

AEM 30-71XX Infinity Stand-Alone Programmable Engine Mangement System Full Manual User Manual

Page 80

background image

74

© 2014 AEM Performance Electronics

Infinity User Manual

4) Begin the Firmware Upgrade process.

a. Select the desired Configuration “Image” on the left.

i.

If no images are present check C:\Program Files (x86)\AEM\Infinity Tuner\ and verify
.pakgrp file is there. If not, visit

http://www.aeminfinity.com

, log in, and download

appropriate file.

b. Ensure "Keep Calibration Data" check-box is marked to save current calibration.
c. Click the “Begin” button to start the upgrade process.

5) Follow the message at the bottom, and turn the ignition switch OFF when instructed to do so.