beautypg.com

Vr pwmduty [%] tables – AEM 30-71XX Infinity Stand-Alone Programmable Engine Mangement System Full Manual User Manual

Page 276

background image

270

© 2014 AEM Performance Electronics

Infinity User Manual

VR PWMDuty [%] Tables

A variable voltage threshold for VR inputs is set by editing these two tables. The channel is a %
duty and corresponds to threshold voltages as shown in the table below. We recommend leaving
the RPM breakpoints as set from AEM and as shown in the examples.

VR_Pwm Duty [%]

Trigger Threshold [V]

20

0.08

30

0.21

40

0.40

50

0.58

60

0.78

70

1.10

80

1.48

90

2.06

95

2.38

100

2.76

The table below describes which VR_PwmDuty table is used for each VR input.

Hardware Platform

Harness Pin

Hardware Ref.

VR PWMDuty [% ]
Table

Infinity-8/10/12

C1-45/C1-46

Crankshaft Position
Sensor VR+_In

VR_PwmDuty [%]