112

© 2014 AEM Performance Electronics

Infinity User Manual

Value used to smooth signal. Min value = 0, Max value = 60.

Mode Select:

ModeSelect_DBW x-axis input:
Input for choosing between different DBW throttle curves. See

Advanced Tuning -> Multi-Map

Features

for details on changing throttle curves on the fly.

Error Response:

DBW Error Rev Limit:
RPM limit before fuel and spark will be cut off. Min value = 0, Max value = 3000.

DBW Tracking Errors at 0 RPM:
Enable or disable tracking errors when Engine Speed is at 0 RPM.