beautypg.com

AEM 30-71XX Infinity Stand-Alone Programmable Engine Mangement System Full Manual User Manual

Page 112

background image

106

© 2014 AEM Performance Electronics

Infinity User Manual

manufacturer specifications for more information. Min value = 0, Max value = 5. Oil Pressure
Max Volts must be > Oil Pressure Min Volts. User entries that do not meet this criteria are not
allowed.

Oil Pressure Cal Min [psig]:
This sets the minimum pressure capable, in psig, from a properly working sensor. Check the
manufacturer specifications for more information. Min value = 0, Max value = 200. Oil
Pressure Cal Max must be > Oil Pressure Cal Min. User entries that do not meet this criteria
are not allowed.

Oil Pressure Cal Max [psig]:
This sets the maximum pressure capable, in psig, from a properly working sensor. Check the
manufacturer specifications for more information. Min value = 0, Max value = 200. Oil
Pressure Cal Max must be > Oil Pressure Cal Min. User entries that do not meet this criteria
are not allowed.

Oil Pressure Failsafe On:
When clicking, the failsafe feature is enabled. This is typically used when the sensor is
mistakenly unplugged or has failed.

Oil Pressure Failsafe:
The value entered here will be displayed and used for the oil pressure corrections when the
sensor has failed or is simply unplugged. Min value = 0, Max value = 150