beautypg.com

AEM 30-2066 K-Type Closed Tip Thermocouple 10 Wiring Extension Kit User Manual

K-type thermocouple extension harness

background image


ADVANCED ENGINE MANAGEMENT INC.

2205 126

th

Street Unit A Hawthorne, CA. 90250

Phone: (310) 484-2322 Fax: (310) 484-0152

Http://www.aempower.com

Instruction Part Number: 10-2066

© 2009 Advanced Engine Management, Inc.

K-Type Thermocouple Extension Harness

The 30-2066 K-Type Thermocouple Extension Harness kit contains a 10’ thermocouple
grade extension harness, along with mounting hardware to mate with the AEM 30-2065
K-Type Thermocouple. The sensor end of the harness contains two ring terminals that
connect to the 30-2065 K-Type thermocouple, see figure 1 below for details on
connecting to the K-Type thermocouple. The other end of the harness contains a 3-
position single row connector that mates with various AEM EGT devices. For use with a
different style of connector, the harness can be cut and reterminated. NOTE: Pay
special attention to polarity and wire color when reterminating. YELLOW IS POSITIVE,
RED IS NEGATIVE.

Connecting the Extension Harness and Thermocouple

Slide the supplied heat shrink onto the sensor cable. Connect the RED wire from the
thermocouple to the RED wire on the harness and the YELLOW wire from the
thermocouple to the YELLOW wire on the harness using the supplied 4-40 screws and
hex nuts. Make sure the connections are not touching. Center the heat shrink over the
connections and apply mild heat to the heat shrink until it shrinks over the connections.





Kit Contents:
1 x 10’ Extension Harness
2 x 4-40 Hex Nut
2 x 4-40 Screw
1 x Heat Shrink, 6”




HEAT SHRINK

Figure 1. K-Type Thermocouple Connection