Lean Protection Minimum Throttle (% ):
Only lean conditions above this set throttle position will be monitored for the lean
protection feature.
Min value = 0, Max value = 100, Resolution = 1.0

Lean Protection Activation Delay:
This can be used to cancel out any false spikes caused by excessive EMI signal noise.
Min value = 0, Max value = 2000, Resolution = 1.0

Lean Protect Rev Limit (RPM):
This sets the engine speed limit when the lean protection is triggered.
Min value = 0, Max value = 20000, Resolution = 1.0