Total Access 1200F Conversion

61179641AL4-5B

3-17

TOTAL ACCESS 1200F CONVERSION

CAUTION

The order of subtended Total Access 1200 Series DSLAMS must be
preserved when connecting to the Total Access 1200F for transla-
tion to the legacy ATM mode PVCs. See

Table 3-7

.

Existing Total Access 1200 Series DSLAM installations require a software upgrade to convert
the Total Access 1200 Series DSLAMs to function with a Total Access 1200F.
To upgrade each Total Access 1200 Series DSLAM, perform the following steps:

CAUTION

Upgrading the firmware disrupts DSL service to the customer.

1. Connect a VT100-capable laptop/terminal to the

CRAFT

port of a Total Access 1200 Series

DSLAM (see

Figure 3-11

for the location of the

CRAFT

port).

Figure 3-11. Total Access 1100 Series DSLAM Craft Port

2. Set the terminal baud rate to 9600 baud, 8 data bits, no parity, 1 stop bit, and no flow

control.

NOTE

The 4-MB Flash Upgrade must be made at 9600 baud.

Table 3-7. Order of Subtended Clients

Total Access 1200F Expansion Port

Total Access 1200 Series Client

1

Total Access 1100 Series Host

(Client 1)

2

Client 2

3

Client 3

4

Client 4

PORTS 1-24

ALARM

CRAFT