beautypg.com

Front panel leds, Front panel leds -3, Figure 1-2 – ADTRAN 1248 User Manual

Page 19: Total access 1248 front panel leds -3, Table 1-1

background image

Description

61179641AL4-5B

1-3

Front Panel LEDs

Figure 1-2

shows the location of the Total Access 1248 front panel LEDs. Upon initial

powering, the Total Access 1248 system performs a power up self-test. Once the power up
self-test is complete, the status LEDs reflect the condition of the hardware.

Figure 1-2. Total Access 1248 Front Panel LEDs

See

Table 1-1

for a listing of LEDs and their status.

Table 1-1. Front Panel LEDs

Label

Status

Description

PWR

Green

Yellow

Red

Off

Total Access 1248 is In Service
Total Access 1248 is Out of Service-Maintenance
Total Access 1248 Failed self-test
No power present on Total Access 1248

ALM

Yellow

Red

Off

Total Access 1248 is reporting a Minor alarm
Total Access 1248 is reporting a Major alarm
No alarms reported on Total Access 1248

T1/E1 1–8

Green

Green Flashing

Yellow

Yellow Flashing

Red

Off

All good
T1/E1 OK, no IMA Sync
Signal present OOF
T1/E1 is in loopback
No signal
Facility unassigned

ETHERNET

Green

Green Flashing

Yellow

Ethernet signal present
Ethernet with traffic
No signal

EXPANSION OUT

Green

Green Flashing

Yellow

Connected to a downstream box
Connected with traffic
No signal

FAN MODULE

1179675L1

1179641AL4

PORTS 1-24

5.0A

CTORS ONLY!

PWR

ALM

ETHERNET

OUT

EXPANSION

T1/E1

5

6

7

8