beautypg.com

T1 performance monitoring status screen, T1 performance monitoring status screen -101, Table 5-67 – ADTRAN 1248 User Manual

Page 153: T1 performance monitoring status screen codes -101, T1 performance monitoring, Status screen

background image

Menu Descriptions

61179641AL4-5B

5-101

T1 Performance Monitoring Status Screen

T1 Performance Monitoring Status

Main Menu

\

Network Port

\

T1 Main Menu

\

T1 PM

\T1 Performance Monitoring Status\

The T1 Performance Monitoring Status screen (see

Figure 5-66

) displays performance

monitoring in 24-hour and 15-minute increments for the current port selected.

NOTE

To display the Abbreviations screen, press “

?

”.

Figure 5-66. T1 Performance Monitoring Status Screen

The T1 Performance Monitoring Status screen codes are shown in

Table 5-67

.

Table 5-67. T1 Performance Monitoring Status Screen Codes

Code

Definition

Description

UAS-P

Unavailable Seconds

This code indicates seconds with a loss of signal or
synchronization on the path.

ES-P

Errored Seconds

This code indicates seconds with either a bipolar
violation or a CRC-6 error on the path.

SES-P

Severely Errored Seconds

This code indicates seconds with 1544 bipolar violations
or 320 CRC-6 errors on the path.

TID: TA1248 Total Access 1248 MM/DD/YY HH:MM
Unacknowledged Alarms: None
T1 Performance Monitoring Status - T1 Port:1

UAS-P ES-P SES-P CV-P CV-L ES-L
24 Hr - Current 24845 0 0 0 0 0
--/-- - - - - - -

15 Min - Current 784 0 0 0 0 0
08:30 900 0 0 0 0 0
08:15 900 0 0 0 0 0
08:00 900 0 0 0 0 0
07:45 900 0 0 0 0 0
07:30 900 0 0 0 0 0
07:15 900 0 0 0 0 0
07:00 900 0 0 0 0 0
06:45 900 0 0 0 0 0

B - Backward(2hrs/15min PM) F - Forward(2hrs/15min PM)
S - Select Port P - Previous Port N - Next Port C - Clear PM Stats
'?' - System Help Screen