IMA Group 1 Failure Monitoring Status Screen
IMA Group 1 Failure Monitoring Status
\
\
\IMA Group 1 Failure Monitoring Status\
The IMA Group 1 Failure Monitoring Status screen (see
) displays the status of the
group state and the Near End and
Far End
failure status.
Figure 5-87. IMA Group 1 Failure Monitoring Status Screen
The IMA Group 1 Failure Monitoring Status screen fields are shown in
.
Table 5-89. IMA Group 1 Failure Monitoring Status Screen Fields
Field
Description
NE Group State
This field displays the Near End group status.
FE Group State
This field displays the Far End group status.
NE Failure Status
This field displays the Near End failure status.
FE Failure Status
This field displays the Far End failure status.
Link With Least Delay
This field displays the link with the least delay.
Max Link Differential Delay
This field displays the maximum link differential delay.
Configured TX Links
This field displays the number of transmitting links that are
configured.
Active Tx Links
This field displays the number of transmitting links that are
active.
Configured RX Links
This field displays the number of receiving links that are
configured.
TID: TA1248 Total Access 1248 MM/DD/YY HH:MM
Unacknowledged Alarms: None
IMA Group 1 Failure Monitoring Status
NE Group State : Operational
FE Group State : Operational
NE Failure Status : No Failure
FE Failure Status : No Failure
Link With Least Delay : 1
Max Link Differential Delay : 0
Configured TX Links : 8
Active Tx Links : 8
Configured RX Links : 8
Active Rx Links : 8
FE Failure Data : Unavailable
FE Frame Length : 32
Group Version : Unknown
Timing Source : Port 1
Last Timing Source Change : MM/DD/YY HH:MM:SS
'?' - System Help Screen