beautypg.com

2 on-the-spot diagnosis, On−the−spot diagnosis, 2 on−the−spot diagnosis – Festo Кабели и принадлежности User Manual

Page 85: Description of the led signals

background image

5. Diagnosis and error treatment

5−4

Festo P.BE−SPC200−SMX−1−EN en 0503b

5.2

On−the−spot diagnosis

The two LEDs on the stepping motor indexer module enable a
speedy on−the−spot diagnosis to be made:

ć

FAULT LED (red)

ć

STATUS LED (green)

FAULT LED
(red)

STATUS LED
(green)

Operating status

is off

is off

Operating voltage not applied

lights up

is off

Function card has not started; SPC200 defective or function card
defective; servicing required

lights up

flashes for a
long time

Limit switch actuated, short circuit or incorrect polarity at sensor
input or internal fault

is off

flashes briefly

Initialization phase Reference travel not carried out or reference
travel no longer valid (Servo Ready interrupted)

is off

flashes for a
long time

Operating status normal no axis movement/positioning task

is off

lights up

Axis moves

Description of the LED signals

Signal

Description

Signal

Description

ON

OFF

is off

ON

OFF

flashes for a long
time

ON

OFF

lights up

ON

OFF

flashes briefly