1−12

Festo P.BE−SPC200−SMX−1−EN en 0503b

1.6

EMERGENCY STOP concept

Please note
Check within the framework of your EMERGENCY STOP
concept, to ascertain the measures necessary for putting
your machine/system into a safe state in the event of an
EMERGENCY STOP (e.g. switching off the load supply,
operating voltage for the stepping motor controller,
switching off the compressed air).

The status of the limit switches connected to the sensor plug
is evaluated by the operating system of the SPC200.

Warning
The limit switches connected to the sensor plug are not
suitable for implementing an EMERGENCY STOP function.

Use additional separate safety limit switches if an apĆ
propriate EMERGENCY STOP circuit is required for your
application.