4. Commissioning
4−28
Festo P.BE−SPC200−SMX−1−EN en 0503b
4.4.1 Setting project−specific parameters
Cautio
Incorrectly set parameters can lead to uncontrolled reacĆ
tions of the connected axes during operation.
The SPC200 must know the conditions of use in your project
and the type of components used in your positioning system.
Undertake the necessary settings in the following menus:
Menu
Description
SPC200 READY
AXIS PARAM.
>
Axis parameters;
Specifications on the axes used
SPC200 READY
APPLIC. PARAM.
>
Application parameters;
Specifications on the conditions of use
When you have selected a menu, use the arrow buttons to set
the axis identifiers of the stepping motor axis to be confiĆ
gured and confirm this with the ENTER key:
AXIS PARAM. >>
X: