4. Commissioning
4−24
Festo P.BE−SPC200−SMX−1−EN en 0503b
Fig. 4/7: Dialogue window Commission stepping motor"
Checking the inputs
2. Make sure that the end and reference switches function
correctly. In order to do this, you can move the axis by
hand when the stepping motor controller is switched off.
Select the desired stepping motor axis under Axis
selection." Check the checkboxes of the relevant inputs
under Status of the inputs."
Note the different designs of sensors:
ć
Limit switches (end switches): N.C., normally closed
ć
Reference switch: N.O., normally open