beautypg.com

2 configuration of the axis parameters, Configuration of the axis parameters – Festo Кабели и принадлежности User Manual

Page 56

background image

4. Commissioning

4−11

Festo P.BE−SPC200−SMX−1−EN en 0503b

4.3.2 Configuration of the axis parameters

Check and, if necessary, correct the settings in the register
card Axis parameters" in accordance with your system.

Description of the parameters under
AxisĂparameters"

The axis parameters are configuration data which describe
the composition, the properties and the components of the
axis used.

When an axis is inserted from the Planning Tool, the appropriĆ
ate information on the linear drive is shown in the display
fields. After an upload these fields appear empty, as this inĆ
formation is not saved in the SPC200.

Designation

The designation of the linear drive used for the electric axis
(display field).

Length

The length of the linear drive used for the electric axis
(see type plate).

Permitted: 50 ... 10.000 [mm]

Diameter

The size of the linear drive used for the electric axis
(see type plate, parameter only for information).

Permitted: 8 ... 320 [mm]

Motor

The designation of the stepping motor used for the electric
axis (display field).

Steps/turn

The number of steps per turn of the stepping motor used for
the electric axis (display field).

Gear

The designation of the gear used for the electric axis (display
field).