3. Installation
3−9
Festo P.BE−SPC200−SMX−1−EN en 0503b
1
1
2
8
.
.
.
9
15
.
.
.
1
AMPLIFIER connection
Fig. 3/4: Control plug (AMPLIFIER, X30)
Pin assignment of control plug (AMPLIFIER, X30)
Pin
Signal
SEC−ST
Pin
Signal
SEC−ST
1
+ PULSE
Clk + 5
9
− PULSE
Clk −
2
+ DIRECTION
Dir + 5
10
− DIRECTION
Dir −
3
+ ENABLE
En + 5
11
− ENABLE
En −
4
Not connected
ć
12
Not connected
ć
5
+ F/H STEP (full/half step)
ć
1)
13
Not connected
ć
6
− F/H STEP (full/half step)
ć
1)
14
Not connected
ć
7
Not connected
ć
15
− READY
ć
1) 2)
8
+ READY
ć
1) 2)
1)
Not used with stepper motor controller SEC−ST
2)
Connections bridged in the connecting cable