Festo Кабели и принадлежности User Manual
Page 50
4. Commissioning
4−5
Festo P.BE−SPC200−SMX−1−EN en 0503b
The settings of the maximum phase current depend on the
stepping motor connected. The maximum permitted phase
current is specified on the type plate of the stepping motor.
Caution
Excessive currents can damage the motor.
Do not set a current higher than that specified for the
motor, as otherwise the motor will be overloaded.
Select the next lower value if the specified current cannot be
set.
Please refer to the documentation on the stepping motor conĆ
troller for the correct pre−settings and for instructions on optiĆ
mizing the settings.
Switching on the power supply on the SPC200
Please note
Make sure that the axis is always within the positioning
range defined by the limit switches when it is switched on
and before the start of reference travel.
When you have checked the installation and parametrizing of
the stepping motor controller, switch on the power supply for
the SPC200.