3 commissioning with winpisa, Commissioning with winpisa – Festo Кабели и принадлежности User Manual
Page 52
4. Commissioning
4−7
Festo P.BE−SPC200−SMX−1−EN en 0503b
4.3
Commissioning with WinPISA
For commissioning with WinPISA you must simulate the
existing hardware configuration in WinPISA. Refer here to the
WinPISA manual for the necessary steps.
With the existing stepping motor indexer module there are
one or several stepping motor interfaces in the project winĆ
dow under the SPC200. A stepping motor axis is assigned to
each stepping motor interface.
Fig. 4/1: Stepping motor interface
Configuring the axis
In order to configure a stepping motor axis, select the icon of
the axis in the project window. With the command [Edit]
[Configure] or with a double click on the axis icon, you can
open the relevant dialogue window Parameter set for the
..Ăaxis."
Caution
Incorrectly set parameters can lead to uncontrolled reacĆ
tions of the connected axes during operation.