2.4 SPECIFICATIONS

CATEGORY

REQUIREMENTS

Environmental

Operating Temperature

–31F to +150F

(-35C to +66C) @ 30 VDC

Operating Humidity

5% to 95% relative humidity,

non-condensing

Electrical

Power Supply/Current
Requirements

10 - 15V DC, linear, filtered and regulated power
supply recommended 150 mA for the EntryProx
unit only.

Additional capacity or separate supply required for
locking device or peripherals.

Mechanical

Height

5.25 in (13.3 cm)

Width

2.75 in (7 cm)

Depth

1.625 in (4.1 cm)

Relay Outputs

Main Relay, Aux Relay

Form C (switches up to 1A inductive load, 2A
resistive @ 30VDC)

Sounder

4000 Hz, defeatable

LEDs

Bi-Color

(red/green)

Amber

Infrared

Page 6 of 58

February 7, 2007