beautypg.com

HID EntryProx Installation Guide User Manual

Page 54

background image

Part No. 4045-905, Rev C.2 EntryProx

User Guide

IF YOU WANT

Ref

PRESS

DETAILS

TO

27 Download

Transaction Log
via IR port

70 # 0 # 0 # **

Hold optional Palm PDA IR
receiver near the EntryProx
IR LED.

28 Set

transaction

log mask
(set/clear event
logging)

73 # event # set/
clear # **

Prevent specified
transactions from being
logged.

Set =0 (prevent)

Clear = 1(restore)

See the following Code -
Transaction Event
list.

Code – Transaction Event

01 – Access Denied

02 – Program Denied

04 – Request to Exit

05 – Door Ajar

06 – Door Closed

07 – Forced Door

10 – Invalid PIN Lockout

12 – Facility Code Access

16 – Download to PDA

17 – Access

20 – Toggle ON

21 – Toggle OFF

24 – Lockout ON

25 – Lockout OFF

27 – Mismatch

29 – Program Mode started

30 – Log erased

29 Reset

transaction 76 # 00000 #

Log

00000 # **

30

To exit Program

* (after final

yellow LED stops flashing

mode

command)

Page 54 of 58

February 7, 2007