Part No. 4045-905, Rev C.2 EntryProx
™
User Guide
5.1 MAIN RELAY
The main relay for the door-locking device is wired to connector
P1 on the EntryProx main circuit board.
5.2
GATE ACTUATOR
You can make the wire connections for a gate actuator by
connecting the Blue (C) wire and the Green (N/O) wire directly to
the input.
Note: DO NOT connect a power supply to the relay if you connect
a gate actuator.
5.3
AUXILIARY RELAY
The EntryProx unit has an auxiliary relay feature that allows for
customized alarm programming. Pins 1, 2, and 3 on the P2
connector can be wired for one of the following alarm outputs:
•
• Alarm shunt
•
• Forced or propped door
The alarm shunt operation allows you to use the auxiliary relay to
bypass a door contact that is monitored by a separate alarm
system. If the entry or exit is controlled by the EntryProx unit, an
intrusion alarm will not be generated if the door is opened using an
access card or PIN number, or by pressing the REX button.
The forced or propped door alarm allows you to use the auxiliary
relay to provide a local warning, such as an audible or visual
indicator if:
•
• A door is opened without using an access card or PIN
number at the EntryProx unit.
•
• A door is legitimately opened but is held open too long.
Note: The auxiliary relay audible and visual indicators and the
door open times can be programmed. Refer to Table 1
Programming Commands for more information.