beautypg.com

1 main relay, 2 gate actuator, 3 auxiliary relay – HID EntryProx Installation Guide User Manual

Page 24

background image

Part No. 4045-905, Rev C.2 EntryProx

User Guide

5.1 MAIN RELAY

The main relay for the door-locking device is wired to connector
P1 on the EntryProx main circuit board.

5.2

GATE ACTUATOR

You can make the wire connections for a gate actuator by
connecting the Blue (C) wire and the Green (N/O) wire directly to
the input.

Note: DO NOT connect a power supply to the relay if you connect
a gate actuator.

5.3

AUXILIARY RELAY

The EntryProx unit has an auxiliary relay feature that allows for
customized alarm programming. Pins 1, 2, and 3 on the P2
connector can be wired for one of the following alarm outputs:

• Alarm shunt

• Forced or propped door

The alarm shunt operation allows you to use the auxiliary relay to
bypass a door contact that is monitored by a separate alarm
system. If the entry or exit is controlled by the EntryProx unit, an
intrusion alarm will not be generated if the door is opened using an
access card or PIN number, or by pressing the REX button.

The forced or propped door alarm allows you to use the auxiliary
relay to provide a local warning, such as an audible or visual
indicator if:

• A door is opened without using an access card or PIN
number at the EntryProx unit.

• A door is legitimately opened but is held open too long.

Note: The auxiliary relay audible and visual indicators and the
door open times can be programmed. Refer to Table 1
Programming Commands
for more information.

Page 24 of 58

February 7, 2007

© 2007 HID Global Corporation. All rights reserved.