Part No. 4045-905, Rev C.2 EntryProx

User Guide

4.7 INSTALLATION COMPLIANCE FOR UL

294

The EntryProx Model 4045CGNU0 complies with the UL294
Standard for access control units in a standard, wall-mount
installation, when installed to the following specifications:

Electric locking mechanisms may only be connected to the
NO contacts of the Main Relay. Locking devices requiring
an NC connection may only be used in conjunction with an
interposing relay mounted inside the secure area and
connected to the NO contacts of the Main Relay.

The recommended or equivalent shielded wiring must be
used for the following applications:

Request to Exit input
cable

Alpha 1292C (22AWG) or 2421C
(18AWG)

Wiegand data output
cable

Alpha 1295C (22AWG)

Antenna cable extension

Alpha 1294C (22AWG)

The cable shield drain wires must be grounded at the
reader end by connection to P1, Pin 4 (DC Power
configurations recommended below) by connection to P1,
Pin 4 (DC Power Ground) using appropriate wire nuts or
crimp fittings.

Tamper Switch must be installed in one of the
configurations recommended below, and connected to an
intrusion alarm system. (Refer to Figure 10 for
switch/magnet locations)

4.8

METAL OR PLASTIC SINGLE GANG J-BOX

1. Use an Ademco 945T magnet and reed switch (or

equivalent) with foam-backed adhesive tape.

2. Clip the screw mounting tabs from both the magnet and

reed switch using pliers or a wire cutter.

Page 20 of 58

February 7, 2007