1 stop bit
2 stop bits
These two selections are used to specify the number of stop bits.
The default is 1 stop bit.

No parity
Odd parity
Even parity
These selections are used to specify the parity type. The default is
no parity.

Full-duplex (echo)
Half-duplex (no echo)
These two selections control the duplex mode of the RS232 port.
In full duplex, the management module echoes the characters
received from the terminal back to the terminal. In half-duplex,
the management module does not echo the characters. If each
character typed at the terminal is being displayed twice, select the
half-duplex mode. The default is full-duplex.

Data rate (“baud” rate)
This selection allows you to specify the speed of the port. When
you select this option, the Omega program displays a list of
possible baud rates. Possible baud rates are:

❑ 19200 bps

❑ 9600 bps (recommended setting for fixed baud rate)

❑ 4800 bps

❑ 2400 bps

❑ 1200 bps

❑ 600 bps

❑ 300 bps

❑ 150 bps

❑ 75 bps

❑ Automatic baud rate detection

The default is Automatic baud rate detection.

5. Return to the Main Menu.