Reactivating the default settings on a stack – Allied Telesis AT-S25 User Manual
Page 53

AT-S25 Version 1.4 User’s Guide
53
Reactivating the Default Settings on a Stack
This procedure explains how to reset the stack settings to the factory
default settings, which are listed in Appendix A on page 139. This
procedure can only be performed locally through the RS232 port on the
master switch.
Warning
This procedure should be performed with caution. Resetting a stack
to its default setting deletes all existing settings, including the
stack’s IP address and port settings. Any defined VLANs also are
deleted and all ports are assigned to the Default VLAN.
To reset the stack settings to the factory default settings, perform the
following procedure:
1. Attach a terminal or a PC with a terminal emulation program to the
RS232 port on the front panel of the master switch.
Note
Do not connect the terminal or PC to a slave switch. You must
connect the device to the master switch.
2. Configure the terminal or terminal emulator program as follows:
❑ Baud rate: 9600
❑ Data bits: 8
❑ Parity: None
❑ Stop bits: 1
❑ Flow control: None
Note
These are the default settings for the RS232 terminal interface.
These parameters are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulation program. The Omega program
allows you to change these values. For instructions, refer to
Configuring the RS232 Port on the Master Switch on page 55.
3. Press the Return key.
4. Press the Reset button on the master switch.