beautypg.com

Tting values, 8 setting the trace level – HP Hitachi Dynamic Link Manager Software User Manual

Page 91

background image

HiCommand

®

Dynamic Link Manager (HDLM) for Windows

®

Systems User’s Guide

75

3.5.2.8 Setting the Trace Level

The trace output level can be set.

A trace file in which a trace level can be set is hdlmtrn.log (n indicates a file number
from 1 to 64).

Table 3.13 lists and describes values for the trace level setting.

Table 3.13 Trace Level Setting Values

Value* Description

0: Do not output any trace

No trace is output.

1: Error information only

Only error information is output.

2: Summary of program operation

Program operation summaries are output.

3: Details of program operation

Program operation details are output.

4: All information

All information is output.

*For the

dlnkmgr

command's

set

operation, specify a number such as

0

or

1

.

If an error occurs, you may have to set the trace level to 1 or higher to collect the log
information.

The higher this value is set, the more log information will be output. When the output log is
large, it takes less time to overwrite the old error log information with the new information.

„

Setting by using the Options window

Select Trace level from the pull-down list box.

„

Setting by using the set operation
The following is an example command to set the trace level.

>dlnkmgr set -systflv 1

Specify the trace level in a number.