beautypg.com

HP Hitachi Dynamic Link Manager Software User Manual

Page 248

background image

232

Chapter 7 Command Reference

Setting

Automatic
Failback

Intermittent
Error
Monitoring

Available Operation

Result of Operation

Set intermittent error monitoring to

on

.

„

When a path is being monitored (in the period of

conditional intermittent error monitoring), the value of

the error count and the elapsed monitoring time are

reset to

0

, and then intermittent error monitoring

restarts.

„

When a path is not being monitored (outside the

period of conditional intermittent error monitoring),

nothing changes.

Change the intermittent error

monitoring settings.

„

When a path is being monitored (in the period of

conditional intermittent error monitoring), the value of

the error count and the elapsed monitoring time are

reset to 0, and then intermittent error monitoring

restarts according to the conditions for intermittent

error after change.

1

„

When a path is not being monitored (outside the

period of conditional intermittent error monitoring), the

intermittent error monitoring settings will take effect

when the path is recovered from the error status by

performing automatic failback.

Set intermittent error monitoring to

off

.

„

Intermittent error monitoring is disabled.

„

The error count, elapsed monitoring time, and

information about paths not subject to automatic

failback are cleared.

Set automatic failback to

on

.

The operations of automatic failback and intermittent error

monitoring do not change.

Change the automatic failback

setting.

Automatic failback operates using new settings.

off

Set automatic failback to

off

.

Automatic failback is disabled.

on

off

Set intermittent error monitoring to

on

.

Intermittent error monitoring is enabled.

1

Set automatic failback to

on

.

Automatic failback and intermittent error monitoring are

enabled.

1

on

2

Set automatic failback to

off

.

The operations of automatic failback and intermittent error

monitoring do not change.

Set automatic failback to

on

.

Automatic failback is enabled.

off

off

Set automatic failback to

off

.

The operations of automatic failback and intermittent error

monitoring do not change.

1

When this condition is not satisfied, the KAPL01080-W message is output and an error occurs. The status of the intermittent

error monitoring does not change.