Chapter 7 Command Reference

Displayed LU Information

Table 7.15 describes the displayed LU information. The following explains the table
headings.

Table 7.15 Displayed LU Information

Displayed Item

No Summary
Displayed

1

Summary
Displayed

2

Description

Product

ƒ

For the Thunder 9200/9500V Series, Lightning 9900/9900V Series,

TagmaStore, and Universal Storage Platform V: Model name of the storage

system

ƒ

For the EMC DMX series and EMC CX series: Vendor ID

ƒ

For the HP EVA series:
Vendor ID_Product ID

Serial
Number

S/N

ƒ

For the Thunder 9200/9500V Series, Lightning 9900/9900V Series,

TagmaStore, and Universal Storage Platform V: Serial number of the storage

system

ƒ

For the EMC DMX series, EMC CX series, and HP EVA series: A hyphen (-) is

displayed.

LUs

Total number of LUs managed by HDLM among the LUs in the storage system

iLU

ƒ

For the Thunder 9200/9500V Series, Lightning 9900/9900V Series

TagmaStore, and Universal Storage Platform V: LU number in the storage

system
This number combined with the storage system name (shown in

DskName

)

identifies the LU that is accessed by a path.
For the TagmaStore USP, Lightning 9900V Series, and Lightning 9900 Series,

the first two characters of

iLU

are the CU (Control Unit) number, and the last

two characters are the internal LU number within the CU. Indicated by a

hexadecimal number. For the TagmaStore AMS/WMS series, Thunder 9500V

Series, and Thunder 9200 Series, the entire value of

iLU

is the internal LU

number within the storage system. You can identify an actual LU by

referencing

iLU

from the storage system management program. Indicated by

a decimal number. For Universal Storage Platform V, indicated by a

hexadecimal number. The first two characters of

iLU

are the number of the

logical DKC (Disk Controller), the middle two numbers are the CU(Control Unit)

number, and the last two characters are the internal LU number within the CU.
For the EMC DMX series, EMC CX series, and HP EVA series: The ID that

differs from the LU number in the storage system and that identifies the LU is

indicated by a hexadecimal number. The value of

iLU

consists of 32 digits.

The first 13 digits of

iLU

are displayed, and periods (

...

) are displayed for the

14

th

to 16

th

digits.

SLPR

3

SLPR

4

The number of the SLPR to which the LU belongs, indicated by a decimal number

from 0 to 31. A hyphen (

-

) is displayed if the storage logical partition functionality

for the storage system for the target LU is not supported.

HDevName

3,5

-

Host device name.
A drive letter is displayed. If no drive letter has been assigned, a hyphen (-) is

displayed. The drive letter is displayed in the

HDevName

field even if the value of

the

DNum

field is

0

. Note, however, that the displayed drive letter is the drive letter

for one of the Devs included in the LU.