beautypg.com

HP Hitachi Dynamic Link Manager Software User Manual

Page 271

background image

HiCommand

®

Dynamic Link Manager (HDLM) for Windows

®

Systems User’s Guide

255

Displayed Item

No Summary
Displayed

1

Summary
Displayed

2

Description

IEP

Not

displayed

Information about the intermittent error. This item is displayed only when you specify

-

iem

with the

-path

parameter. One of the following values is displayed for each path:

„

- i

ndicates that intermittent error monitoring is disabled or the monitoring time for

an intermittent error is out of range (the path status is Online(E) or Offline(E)).

„

A value of at least 0 indicates the number of errors that occurred during intermittent

error monitoring (the path status is Online(E), Offline(E), or Online).

„

* i

ndicates that an intermittent error occurred (automatic failback does not check

the path) (the path status is Online, Online(E), or Offline(C)).

1

No summary displayed indicates that the user specifies the

-path

parameter or

-path

-item

parameter.

2

Summary displayed indicates that the user specifies the

-path

-c

parameter.

3

The path information is displayed only when a value is specified for the

-path -item

parameter.

4

In a cluster configuration, an

offline

operation requested during reserve processing is put into the waiting-to-execute state,

and does not execute until the reserve processing finishes.

5

The drive letter assigned to a dynamic disk volume is not displayed.

Table 7.12 describes the elements of a path name.

Table 7.12 Elements of a Path Name

Element

Windows Representation

Host port number (hexadecimal) (example: 0004, 0005)

SCSI port number

Bus number (example: 0001)

SCSI bus number

Target ID (example: 0000000000000000,

000000000000007A)

Target Id

Host LU number0001)

Logical Unit ID or LUN

The path name corresponds to the following information:

„

Information shown in the Computer Management window.

„

The information in the following registry:

HKEY_LOCAL_MACHINE\HARDWARE\DEVICEMAP\Scsi

Note: When an FC connection is used, the target ID of a SCSI is determined based on the HBA
configuration. For details on the target ID, see the relevant documentation, such as the HBA
manual.