HP Hitachi Dynamic Link Manager Software User Manual
Page 56
40
Chapter 2 HDLM Functions
User Operation
Number of Errors and
Time Passed since Error
Monitoring Started
Information about Paths
not Subject to
Automatic Failback
Changing the setting for intermittent
error monitoring to outside the
intermittent error monitoring.
(Not applicable) (Not
counted.)
Inherit
Changing the automatic
failback settings
Setting
off
Reset
Reset
Placing the path Offline(C)
Reset
Reset
Placing the path Online outside the
intermittent error monitoring
(Not applicable) (Not
counted.)
Reset
Changing the path status
Placing the path Online during
intermittent error monitoring
Inherit
(Not applicable)(If a path
has been removed from
the paths subject to
automatic monitoring, that
path is not monitored.)
Restarting the HDLM manager
Reset
#4
Inherit
Restarting the host
Reset
Reset
1
When you change the intermittent error monitoring functionality to off, information about paths not subject to automatic
failback will be reset. When you change the intermittent error monitoring functionality to off and you do not want to reset
information about paths not subject to automatic failback, place the target paths Offline(C).
2
The number of errors is reset to
0
, and then monitoring restarts in accordance with the changed monitoring conditions.
3
If the settings for a function other than intermittent error monitoring have been changed or the settings for intermittent error
monitoring have not been changed, and then the Apply or OK button is clicked, the number of error occurrences and the time
since monitoring started are reset. To leave the setting unchanged, close the Options window by clicking the Cancel button. If
you want to change the settings for a function other than intermittent error monitoring but do not want to reset the intermittent
error monitoring status, use an HDLM command.
4
The number of errors is reset to
0
, and then monitoring restarts.