beautypg.com

Snmp traps – HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual

Page 43

background image

Domain management 43

For Flex-10 connections, threshold and link state change traps reflect the state of the entire physical port.

These traps are not generated for individual FlexNICs. For more information on Flex-10 connections,

see "Flex-10 overview (on page

98

)."

When upgrading from VC v2.10 to VC v2.3x or higher, the VC 2.10 SNMP configuration is converted

to a comparable VC 2.3x or higher SNMP configuration. If a downgrade is performed from VC 2.3x
to v2.10, the SNMP configuration prior to the v2.3x upgrade is restored. Therefore, any changes made

to the 2.3x SNMP configuration are not reflected in the downgraded v2.10 SNMP configuration.

When upgrading from a VC release prior to 3.00, if Fibre Channel SNMP traps were defined with the
DNS type of the Trap Destination address, upon completion of the upgrade, SNMP settings are not

applied to the VC-FC modules. As a solution, use the GUI or CLI to edit any FC SNMP trap destinations

that have a DNS name for the trap destination, and change the DNS name to an IPv4 address.

The following table provides a list of MIBs and where they are supported.

MIB

VC-Enet

VC-FC

RFC 2863 IF-MIB

X

RFC 4188 Bridge-MIB

X

RFC 3418 SNMP v2 MIB

X

X

Compaq System Info MIB

X

X

Compaq Host MIB

X

X

Compaq Rack MIB

X*

Network Mgmt

X

IP-MIB

X

Fibre Alliance MIB (FC Mgmt Integ)

X

Fabric Element MIB

X

VC Module MIB (VCM-MIB)

X

VC Domain MIB (VCD-MIB)

X

* Not supported by the HP 8Gb 24-Port FC module

The VC Module MIB is a VC-specific MIB that describes the state of a specific VC module. In addition to

unique VC module attributes, it defines traps for reporting alerts on port statistics, such as throughput, errors,
and discards. The VC Domain MIB combines domain-wide attributes with traps for state changes in VC

managed objects.
The latest version of the VC-specific MIBs, 8.30b or higher, can be downloaded from the HP Systems Insight

Manager "MIB Kit" site on the HP website
(

http://h18006.www1.hp.com/products/servers/management/hpsim/mibkit.html

).

SNMP traps

The following table provides a summary of the available SNMP traps.

Trap

Category

Severity

MIB

cpqHoSWRunningStatusChangeTrap

VCM Legacy

Corresponds to the

new value of
cpqHoSWRunningStat

us

CPQHOST-MIB

connUnitStatusChange

VC-FC Other

INFO

FA-MIB

connUnitDeletedTrap

VC-FC Other

INFO

FA-MIB

connUnitEventTrap

VC-FC Other

INFO

FA-MIB