HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual
Page 182
Hardware information screens 182
Icon
Operational state
Meaning
Corrective action
(blue)
Initializing
Device is initializing.
Wait until initialization is complete.
(This icon should only be seen at
startup.)
(blue)
Profile pending
Device has a pending profile
assignment.
Turn server power off and apply the
new profile.
(yellow)
Degraded
Device is partially operational, but
capacity is lost.
Check and correct the Onboard
Administrator error condition.
(orange)
Misconfigured
Device has a configuration error.
Correct the Virtual Connect Manager
configuration attributes.
(orange)
Incompatible
Device does not match the
configuration.
BIOS level is not at a level that supports
Virtual Connect.
(orange)
No communication
Cannot communicate with the
device.
Check the physical connections and IP
address.
Missing
Device is configured but not
accessible.
Insert the correct hardware module.
Failed
Device is not operational because
of an error.
Reset the device or application, or
replace the device.
Server Bay OA Communication Status icon definitions
Icon
Operational state
Meaning
Corrective action
OK
Device is fully operational.
None
Failed
Cannot communicate with the
device.
Do one or more of the following:
•
Reset the interconnect module.
•
Check if the physical device is
properly seated in the bay.
•
Check the IP address.
- Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem