Server management 113

Column name

Description

If the speed type is "Preferred", the speed of the network is the same as the

preferred speed of the network to which the connection is associated. If no

preferred speed is configured for a network, it defaults to "Auto".

If the speed type is "Custom", the user can configure any speed from 100Mb
to MAX Configured speed for the network in 100-Mb increments.

PXE

Shows whether PXE is enabled, disabled, or USE BIOS is selected on that

port. Only one port can have PXE enabled for VC-controlled addresses.

MAC

Type of MAC address assignment configured for the Virtual Connect domain

iSCSI HBA Connections

Port

Relative order of the port on the server receiving the profile

Network Name

Name of the network associated with this port selected from list of defined

networks

Status

Displays the current linked status of the selected port

Port Speed

The requested operational speed for the server port. Valid values include

"Auto", "Preferred", and "Custom". The default value is "Preferred".
If the speed type is "Auto", the maximum port speed is determined by the

maximum configured speed for the network.

If the speed type is "Preferred", the speed of the network is the same as the
preferred speed of the network to which the connection is associated. If no

preferred speed is configured for a network, it defaults to "Auto".

If the speed type is "Custom", the user can configure any speed from 100Mb
to MAX Configured speed for the network in 100-Mb increments.

Boot Setting

Shows iSCSI boot connection

MAC

Type of MAC address assignment configured for the Virtual Connect domain

FC HBA Connections

Port

Relative order of the Fibre Channel port on the server receiving the profile

Connected to

Bay number of the VC-FC module to which the port is connected

FC SAN name

Name of the SAN fabric to which the port is connected, or Unassigned

Status

Status of the Fibre Channel module port connected to the server HBA port

Port speed

Speed of the VC-FC module port connected to the server HBA port

WWPN

Type of WWN address assignment configured for the Virtual Connect

domain

FCoE HBA Connections

Port

Relative order of the port on the server receiving the profile

Connected to

Bay number of the VC-FC module to which the port is connected

FC SAN name

Name of the SAN fabric to which the port is connected, or Unassigned

Status

Status of the Fibre Channel module port connected to the server HBA port

Port speed

Speed of the VC-FC module port connected to the server HBA port