HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual
Page 131
Server management 131
Column name
Description
default is "UseBios".
Only one connection can have PXE enabled per profile.
MAC
The MAC address assigned to the port, or "Server Factory Default" if not
using VC-assigned MAC addresses
Mapping
Server hardware mapping assignment. See "Port assignment (on page
)".
iSCSI HBA Connections
Port
Relative order of the iSCSI port on the server receiving the profile
Network Name
Name of the network associated with this port, selected from a list of defined
networks
Status
Status of the network
Port Speed Setting
The requested operational speed for the server port. Valid values include
"Auto", "Preferred", and "Custom".
If the speed type is "Auto", the maximum port speed is determined by the
maximum configured speed for the network.
If the speed type is "Preferred", the speed of the network is the same as the
preferred speed of the network to which the connection is associated. If no
preferred speed is configured for a network, it defaults to "Auto".
If the speed type is "Custom", the user can configure any speed from 100Mb
to MAX Configured speed for the network in 100-Mb increments.
Allocated Bandwidth
Allocated bandwidth of the port. See "Bandwidth assignment (on page
)".
Boot Settings
Enables or disables offload or boot on the network connection. Valid values
are "Primary", "Secondary", and "Disabled". If this value is "Disabled" it
means offload only, no boot. Selecting "Primary" or "Secondary" enables
iSCSI boot.
After selecting an option, you must click outside the grid to complete the
selection. This is the same procedure that is followed when selecting a fabric
or network for an FC or Ethernet connection, respectively. Once the Boot
Setting column has been completed, you can then edit the Target Port Name
and LUN.
MAC
The MAC address assigned to the port, or "Server Factory Default" if not
using VC-assigned MAC addresses
Mapping
Server hardware mapping assignment. See "iSCSI and FCoE port
)".
FC HBA Connections (Physical
ports)
Port
Relative order of the Fibre Channel port on the server receiving the profile
Connected to
Bay number of the VC-FC module to which the port is connected
FC SAN Name
Name of the SAN fabric to which the port is connected, or Unassigned
Status
Status of the Fibre Channel module
Port speed
Speed of the VC-FC module port connected to the port
WWPN
The World Wide Port Name assigned to the port, or "Server Factory Default"
if not using VC-assigned MAC addresses
FCoE HBA Connections
Port
Relative order of the FCoE port on the server receiving the profile
Connected to
Bay number of the VC module to which the port is connected
FC SAN Name
Name of the SAN fabric to which the port is connected, or Unassigned
Status
Status of the VC module
- Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem