Interconnect bay overall status icon definitions – HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual

Page 176

background image

Hardware information screens 176

When adding VC interconnect modules to a VC managed enclosure, wait until the modules have been fully

integrated into the current domain before attempting to make configuration changes to the VC domain. These
changes include adding or editing networks, fabrics, profiles, and shared uplink sets. Verify that the domain

status is clear for the newly added interconnect module before making any changes to the configuration.

Modifying the configuration before the integration is complete can cause unexpected behavior such as

incorrect/invalid connections in a profile.

Special notes on Onboard Administrator removal and

replacement

Replacing the OA in an enclosure containing only one OA causes the OA to leave VC mode. This mode

change requires VC Manager to re-establish credentials with the OA. During this process, VC Manager

rewrites all server settings and sets the state of the servers to "profile recovered." There should not be any

disruption to the servers, but the administrator should be sure that all servers have the correct MAC addresses
and WWNs. Powering off the server clears the "profile recovered" state. If any servers are rebooted or

power-cycled while the credential recovery occurs, the MAC addresses and WWNs might be returned to the

factory default settings.

Interconnect Bay Overall Status icon definitions

Icon

Operational state Meaning

Corrective action

OK

Device is fully operational.

None

Unknown

Device operational state cannot be
determined.

Check Onboard Administrator
communication.

(blue)

Initializing

Device is initializing.

Wait until initialization is complete.

(This icon should only be seen at

startup.)

(yellow)

Degraded

Device is partially operational, but

capability is lost.

Check and correct the Onboard

Administrator error condition.

(orange)

Misconfigured

Device has a configuration error.

Correct the Virtual Connect Manager

configuration attributes.

(orange)

Incompatible

Device does not match the

configuration.

Remove the incorrect hardware. Insert

the correct module.

(orange)

No communication

Cannot communicate with the

device.

Check the physical connections and IP

address.

Missing

Device is configured but not

accessible.

Insert the correct hardware module.

Failed

Device is not operational because
of an error.

Reset the device or application, or
replace the device.

Interconnect Bay OA Reported Status icon definitions

Icon

Operational state

Meaning

Corrective action

OK

Device is fully operational.

None

Unknown

Device operational state cannot be
determined.

Check Onboard Administrator
communication.

Degraded

Device is partially operational, but

capacity is lost.

Check and correct the Onboard

Administrator error condition.