beautypg.com

HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual

Page 163

background image

Hardware information screens 163

Row

Description

Overall Status

Represents the worst condition of OA Reported Status, VC Status, and OA

Communication Status

Hardware Status

Component health status from the Onboard Administrator

VC Status

Component health status from the Virtual Connect Manager

OA Communication Status

Current Virtual Connect Manager to Onboard Administrator communication
state

Rack Name

Name of the enclosure rack (assigned through the Onboard Administrator)

Enclosure Name

Name of the enclosure (assigned through the Onboard Administrator)

Bay

Number of the bay being summarized on this screen

Power

Power state of the device

The following table describes the rows within the Interconnect Bay Information table in the Bay Summary

screen.

Row

Description

Part Number

The part number to be used when ordering an additional module of this type

Product Name

The common descriptive name of the module

Serial Number

The unique serial number of the module

Dip Switch Setting

The current physical setting of the system maintenance switches in a

hexidecimal format, where the least significant four bits of the value

correspond to the four switches and a bit value of 1 indicates the switch is in
the "on" position.

Spare Part Number

The part number to be used when ordering a replacement module of this type

Manufacturer

The manufacturer of the module

Firmware Rev

The current firmware revision of the module

The following table describes the columns within the Uplink Port Information table in the Bay Summary
screen.

Column

Description

Label

Uplink port number

Network(s)

Network name or the name of the shared uplink associated with this port

Status

Displays whether the port is linked or unlinked

Connector Type

Displays the physical type of the faceplate connector, type of pluggable
module if one is present, or "Internal" to indicate the inter-switch link is active

on the VC-Enet module.

LAG ID

Identifies the group of ports that have been aggregated together to form an

802.3ad Link Aggregation Group. This ID is unique only within a single
VC-Enet module, meaning the same LAG ID can be used on different VC-Enet

modules, but it is only meaningful for ports within the same VC-Enet module.