Snmp overview – HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual
Page 42
Domain management 42
The status window displays any problems encountered during the test. When testing is complete, click Close.
SNMP overview
SNMP is used by network management systems to monitor network-attached devices for conditions that
require administrative attention. SNMP consists of a set of standards for network management, including an
Application Layer protocol, a database schema, and a set of data objects.
The SNMP configuration is controlled by the Virtual Connect Manager and applies to all modules in the VC
domain. The SNMP agent software residing on a primary module provides access to managed information
using SNMP protocol. The managed information is presented as a hierarchical database called MIB. Each
element of the managed information is identified by a unique identifier called Object ID. Basic SNMP
support is provided for both the VC-Enet module and the VC-FC module.
Each VC module has an independent SNMP agent that supports a set of MIBs. MIB support for each module
depends both on the type of module (VC-Enet or VC-FC) and the role of the module in the VC domain. A
VC-Enet module can be active, standby, or subordinate based on its ability to run the VC Manager. By
default, the SNMP agent is enabled on VC-Enet modules with a read community string of "public."
The following restrictions and limitations apply:
•
Users must have Administrative privileges to configure SNMP capabilities.
•
The VCM GUI and CLI do not support configuration of threshold trap parameters (high-water mark,
low-water mark, and averaging period).
- Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem