HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual
Page 114
Server management 114
Column name
Description
WWPN
Type of WWN address assignment configured for the Virtual Connect
domain
MAC
Type of MAC address assignment configured for the Virtual Connect domain
Assign Profile to Server Bay
Power
Icon indicates if the server blade is powered on or off (when a server blade is
selected).
Server Bay Assignment
Displays the enclosure name, bay number, and type of server blade
S/N
Serial number of the server blade in the device bay
Model
Model name of the server blade in the device bay
Status
Status of the server blade in the device bay
UID
Icon indicates if the server blade UID is on or off.
If VC-assigned MAC addresses, WWNs, or non-default Fibre Channel boot parameters are being used,
always power off the affected server blades before assigning a profile. When assigning a VC-assigned serial
number (logical), power off the server. To power off a server blade, see "Server Bay status screen (on page
)."
To define a server profile:
1.
Enter the server profile name.
The server profile name can be up to 31 characters in length (no spaces). Because the server profile can
be assigned to different locations, HP recommends that the name reflect the server function. The profile
can be renamed at any time.
2.
To use server factory defaults for Ethernet MAC addresses, Fibre Channel WWNs, or serial numbers
(logical), select the Advanced Profile Settings checkbox. For more information, see "Advanced Profile
)."
3.
Set up Ethernet Adapter Connections for ports 1 and 2. For each port, do the following:
a.
To select an available Ethernet network, click the down arrow in the Network Name field.
b.
Select a network from the previously defined networks.
You can also select multiple networks. For more information, see "Multiple network connections for
a server port (on page
)."
c.
Change the port speed setting:
i.
Click the drop-down arrow in the Port Speed Setting Column.
ii.
Select Preferred, Auto, or Custom. If Custom is selected, set the port speed, and then click OK.
d.
To override the current PXE settings on the server, click the down arrow under PXE and select
Disabled or Enabled.
Only one port can have PXE enabled by Virtual Connect on a server blade. However, if the default
'Use BIOS' setting is selected, the server uses the current settings in the BIOS. On mezzanine cards
only, the 'Use BIOS' selection can allow more than one NIC port to have PXE enabled. Only one
embedded NIC can have PXE enabled.
The MAC field indicates whether the profile uses a server factory default or a VC-defined MAC
address. VC-defined MAC addresses are not assigned until the profile is created.
- Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem