Recovering remote enclosures – HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual
Page 23
HP Virtual Connect Manager 23
•
If the Force Failover checkbox is selected and a Virtual Connect Ethernet module is available in the
alternate interconnect bay, the GUI is redirected to the alternate Virtual Connect Ethernet module for log
on after the Virtual Connect Manager has restarted. Reset times depend on the size and complexity of
the VC Domain configuration.
•
If the Force Failover checkbox is not selected or a Virtual Connect Ethernet module is not available in the
alternate interconnect bay, the Virtual Connect Manager restarts on the current Virtual Connect Ethernet
module, and the user is presented the logon screen for the current Virtual Connect Ethernet module after
Virtual Connect Manager restarts. Reset times depend on the size and complexity of the VC Domain
configuration.
When resetting the Virtual Connect Ethernet module, Virtual Connect Manager is temporarily unavailable to
the user. If failover is specified and a standby Virtual Connect Ethernet module is available, users are logged
off and redirected to the standby Virtual Connect Ethernet module's IP address.
Recovering remote enclosures
If a previously saved configuration file is restored, the OA is reset to factory defaults, or the OA associated
with the remote enclosure is replaced, then the credentials of the remote enclosure must be restored. If the IP
link between the primary enclosure OA and the remote enclosure OA is lost, the remote enclosure is also
marked as NO-COMM. Ensure network connectivity before attempting credentials recovery.
- Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem