beautypg.com

Causes for incompatible status – HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual

Page 161

background image

Hardware information screens 161

Causes for INCOMPATIBLE status

When an interconnect module status is INCOMPATIBLE, details can be viewed in the System log ("

System

Log screen

" on page

50

). The system log provides information about why an interconnect module is marked

incompatible so that proper corrective action can be taken.
The following list provides reasons why an interconnect module might be INCOMPATIBLE and the suggested

corrective actions:

Module adjacency
Typically, interconnect modules installed in adjacent bays must be of the same type. For more
information, see the installation guidelines in the HP Virtual Connect for c-Class BladeSystem Setup and

Installation Guide.
If two adjacent modules are incompatible, both modules are labeled as INCOMPATIBLE, since the rule
applies to both modules.
Corrective action: Remove the adjacent incompatible modules and replace with modules that are
compatible.

Module replacement
If an interconnect module is being used by the domain and is physically removed, and then another
module is installed in the same bay, the new module must be the same type as the module previously

installed in the bay.
If the physically removed module was not being used by the domain, the module can be replaced with
a module of a different type.
VC-Enet modules are considered in use by the domain under the following conditions:

o

Uplinks or downlinks are being used by networks/profiles.

o

The module is the primary VC module, or is in an odd bay of the primary slice.

VC-FC Modules In-Use by the Domain modules are considered in use by the domain if uplinks or
downlinks are being used by fabrics or profiles.
Corrective action: Remove the incompatible module and replace with the previously existing module.
For more information, see "Special notes on interconnect module removal and replacement (on page

175

)."

Firmware version
Only modules with firmware versions supported by the firmware running on the primary module are
compatible. All other versions of firmware modules cause the module to be marked as INCOMPATIBLE.
Corrective action: Use VCSU to update incompatible modules to the appropriate firmware versions for
the domain.

FC bay groups
In a multi-enclosure environment, all enclosures must have the same FC module configuration. For more
information, see the multiple enclosure guidelines in the HP Virtual Connect for c-Class BladeSystem

Setup and Installation Guide.
Corrective action: Remove the incompatible module and replace it with the correct module for the
existing FC bay group.
In a c3000 enclosure, FC modules are not supported in bay 2.