HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual
Page 117
Server management 117
You might need to update the BIOS on the mezzanine card for iSCSI to work. For more information on the
BIOS as well as additional support hardware, see the QuickSpecs on the HP website
The following table describes the fields within the Flex-10 iSCSI connections screen.
Item
Description
iSCSI Boot
Configuration
Initiator Name
Name used for the iSCSI initiator on the booting system. The initiator name length can
be a maximum of 223 characters.
Target Name
Name of the target from which to boot. The target name length is a maximum of 223
characters.
Boot LUN
The LUN of the target identifies the volume to be accessed. Valid values for standard
LUNs are 0-255 decimal. Valid values for extended LUNs are 13- to 16-character
hexadecimal values.
Target Primary IP
Address
Primary IP address used by the iSCSI target
Target Primary Port
The TCP port associated with the primary target IP address. The default value is 3260.
Target secondary IP
Address
Alternate target IP address to use if the primary port is unavailable
Target secondary Port The TCP port associated with the secondary target IP address. The default value is
3260.
Initiator Network
Configuration
VLAN id
The VLAN number that the iSCSI initiator uses for all sent and received packets. Valid
values range from 1 to 4094.
Netmask
IP network mask used by the iSCSI initiator. This value is in dotted decimal format.
Gateway
Default IP route used by the iSCSI initiator. This value is in dotted decimal format.
Authentication Method
CHAP (one-way)
One-way Challenge-Handshake Authentication Protocol. The authentication protocol
- Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem