8

SERVICE

78

ALTOSONIC V12

www.krohne.com

04/2013 - 4002643502 - MA ALTOSONIC V12 R02 en

• Plug the coax cable connector back into the transducer.

• Put back the Delrin protection ring (only for welded meter bodies).
• Put back all covers of the flowmeter.

Figure 8-11: Connecting cable to transducer

1 Insert the coax cable connector into the transducer
2 Make sure that the screw slides in the slot of the transducer

Figure 8-12: Installing of Ex-d plug and cap

1 Plug in the Ex-d connector onto the transducer
2 Put cap on tool and insert it onto the transducer
3 Turn tool clockwise to tighten the cap

Figure 8-13: Tightening securing screw M2

1 Turn Allen key clockwise to tighten the securing screw M2

CAUTION!
After the maintenance work, make sure that no error messages are displayed on the display and
/ or check the correct operation with the Flow Meter Configuration and Monitoring Tool.