Technical data – KROHNE ALTOSONIC V12 EN User Manual
Page 102

9
TECHNICAL DATA
102
ALTOSONIC V12
www.krohne.com
04/2013 - 4002643502 - MA ALTOSONIC V12 R02 en
Display and user interface
Display and user interface
Display and user interface
Display and user interface
Graphic display
LC display, backlit white
Size: 128x64 pixels, corresponds to 59x31 mm = 2.32"x1.22".
Display turnable in 90° steps.
The readability of the display could be reduced at ambient temperatures
below -25°C / -13°F.
Operator input elements 4 optical keys for operator control of the signal converter without opening the
housing.
Display functions
Display functions
Display functions
Display functions
Language of display
texts
English, French, German, Dutch, Russian
Units
Metric and Imperial units selectable from list / free unit.
Measuring accuracy
Accuracy
≤ ±0.2% of measured flow rate, for high pressure flow calibrated.
≤ ±0.1% of measured flow rate, for high pressure flow calibrated and
linearised.
Repeatability
< ± 0.1%
Operating conditions
Temperature
Temperature
Temperature
Temperature
Process temperature
Standard: -20...+70°C / -4...+158°F
Option: -40...+100°C / -40...+212°F
Ambient temperature
-40…+60°C / -40…+140°F
Storage temperature
-40…+60°C / -40…+140°F