INSTALLATION

3

17

ALTOSONIC V12

www.krohne.com

04/2013 - 4002643502 - MA ALTOSONIC V12 R02 en

3.1 Notes on installation

3.2 Storage

Correct storage position

Storage conditions

Maintain the following storage conditions to prevent the equipment from corrosion or early
failure:

• Humidity: <95 % RH (closed and heated storage area)
• Storage temperature: -40...+65º C / -40...+149º F
• Avoid direct solar radiation during long storage periods, store under a sunshade

How to prevent corrosion

Pay attention to the conservation of the inner pipe wall, especially for carbon steel meters.
Typical applications such as measuring dry natural gas (sales quality) or natural gas with a
corrosion inhibitor do not require an anti corrosion coating inside the meter tube. A coating can
even be regarded as unwanted because it may wear off, which will have an impact (although
minor) on the accuracy.

CAUTION!
Inspect the packaging carefully for damages or signs of rough handling. Report damage to the
carrier and to the local office of the manufacturer.

INFORMATION!
Do a check of the packing list to make sure that you have all the elements given in the order.

INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.

Figure 3-1: Storage

1 Correct position for all sizes
2 Position not allowed for flowmeters > 12"

WARNING!
Make sure that the extensions on the bottom of the flanges are in good order to prevent the
meter from rolling over. Otherwise take appropriate measures to prevent the meter from rolling
over.