MODBUS PROTOCOL DESCRIPTION AND SET-UP

10

139

ALTOSONIC V12

www.krohne.com

04/2013 - 4002643502 - MA ALTOSONIC V12 R02 en

Flowmeter configuration

Relative
address

Absolute address

Name

Parameter /
Variable
(short description)

non-Modicon

Modicon-comp.

1

7501

7502-7503

(2 regs)

Diameter

Internal diameter

Internal diameter of meter body at the

measuring section (in m).

2

7502

7504-7505

(2 regs)

MeterConstat_Fwd

Meter constant

forward

Meter constant, forward flow direction.

3

7503

7506-7507

(2 regs)

MeterConstant_Rev

Meter constant

reverse

Meter constant, reverse flow direction.

4

7504

7508-7509

(2 regs)

ThermExp_Alpha_Pip

e

Thermal expansion

factor

pipe material Alpha

Property of the material of the meter body,

used to calculate the effect of themal

expansion (in 1/° C)

5

7505

7510-7511

(2 regs)

ThermExp_Reference

_Temp

Reference

temperature

Body expansion

Temperature (in ° C) at which the internal

diameter of meter body at the measuring

section is specified.

6-11

7506-7511

(6 regs)

7512-7523

(12 regs)

Ch_PathLength_Cal

Channel Calibrated

Path

Length L,

channel 1-6

Length (in m) of acoustic path length between

two transducers of a measuring path; array

with values for channel 1 through 6.

12-17

7512-517

(6 regs)

7524-7532

(12 regs)

Ch_Angle_Measuring

Channel Measuring

Angle

channel 1-6

Angle at which the ultrasonic beam intersects

with the meter body (in Deg); array with values

for channel 1 through 6.

18

7518

7536-7537

(2 regs)

Fwd_MaxFlowRate

Flow Full Scale

Forward

Indicated value (in m

3

/s) (full scale) at flow of

100 % of rated volume flow in forward flow

direction.

19

7519

7538-7539

(2 regs)

Rev_MaxFlowRate

Flow Full Scale

Reverse

Indicated value (in m

3

/s) (full scale) at flow of

100 % of rated volume flow in reverse flow

direction.

20

7520

7540-7541

(2 regs)

Fwd_LowFlowCutoff

Low Flow cutoff

Forward

For forward flow rates with smaller

magnitude than this cutoff value, totalisers

stop counting and outputs (such as the

frequency output) will be disabled; flow rate

indication will still be available (in m/s).