Modbus protocol description and set-up – KROHNE ALTOSONIC V12 EN User Manual
Page 135

MODBUS PROTOCOL DESCRIPTION AND SET-UP
10
135
ALTOSONIC V12
www.krohne.com
04/2013 - 4002643502 - MA ALTOSONIC V12 R02 en
Measured / entered process parameters
Calculated flow variables
Relative
address
Absolute address
Name
Parameter /
Variable
(short description)
non-Modicon
Modicon-comp.
25
7025
7050-7051
(2 regs)
TemperatureProces
Temperature process
value
Value used for calculations, can either be the
measured process value, a calculated
(indirectly determined) value or a manual
setting (fixed value) (in °C)
26
7026
7052-7053
(2 regs)
ViscosityDynamic-
Proces
Dynamic Viscosity at
process conditions
Value used for calculations, can either be the
measured process value, a calculated
(indirectly determined) value or a manual
setting (fixed value) (in cP)
27
7027
7054-7055
(2 regs)
DensityProces
Density Process
Value used for calculations, can either be the
measured process value, a calculated
(indirectly determined) value or a manual
setting (fixed value) (in kg/m
3
)
Relative
address
Absolute address
Name
Parameter /
Variable
(short description)
non-Modicon
Modicon-comp.
28
7028
7056-7057
(2 regs)
Flow_Proces
Flow process
Measured volume flow rate at process
conditions (in m
3
/s).
29
7029
7058-7059
(2 regs)
Velo_Proces
Velocity Process
Measured gas velocity (in m/s) (integrated
value from all paths) at process conditions.
30
7030
7060-7061
(2 regs)
SoS
Speed of Sound
Measured speed of sound (in m/s), average of
all acoustic paths, corrected for mach effect.
31-36
7031-7036
(6 regs)
7062-7073
(12 regs)
Ch_VeloRaw
Channel Velocity
Channel 1-6
"Raw" gas velocity as observed on each
channel; array with values for channel 1
through 6 (in m/s).
37-42
7037-7042
(6 regs)
7074-7085
(12 regs)
Ch_SoS
Channel SOS
Channel 1-6
Speed of sound as observed on each channel;
array with values for channel 1 through 6 (in
m/s).